Worcester Bosch Boiler Replacement. Plumber from Viva Training Academy installing a new Viessmann Vitodens 050 Combi Boiler.
We have Paul from Viva Training Academy installing a new boiler.
Make sure you do all your Electrical checks to TB118 Safe Isolation Gas Boilers.
We are also removing an Ideal Isar that's leaking and installing a new Vaillant Combi Boiler

Morning guys. Day in the life of a plumber / gas engineer. Today we’re doing a boiler swap, so we’re taking out an old Ideal logic and we’re going to fit a Baxi Platinum boiler. The reason the customer’s gone for the Baxi Platinum is it’s got a 10 year parts and labour warranty, and it proven, proven reliable boiler over the last 10, 12 years. We’re also going to fit a Nest on this, we’re going to do a MagnaCleanse and we’re going to fit a Fernox filter. So yeah, let’s go inside, let’s go and have a look.

INSTALLING A NEW COMBI BOILER – Step By Step – Magnacleanse – Omega Filter – Baxi Boiler. So I’ve got an Ideal logic 30 in here. So the customer’s been having a few issues with it and wants it replacing for something a bit more reliable, but also wants something with a long warranty. So we’re going to fit them a Baxi, a Baxi boiler in here, with 10 year parts and labour warranty.

So we’ve got all our dust sheets down, and then we’re going to take the boiler out now. So I’m just going to put a test on gas, turn the water off and drain it down. So this has got an old style Spirotech on there, so we will be taking that out and we’ll fit them a Fernox Omega filter.

So just show you, we’re using Press Fit today. So this Press Fit in here, this is gas. So if you have a look at it, it says gas. Now as these get a bit older, and even sometimes now, that wears off a bit and it’s a bit hard to see, which if you go to it on an inspection after might be a bit difficult. But when you’re installing, if you have a look inside, the gas ones have a yellow O ring inside them, and the water ones have a black O ring.

So we’ve got our press gun here and then if we get this pipe and then on there, push this pipe in, and we can mark it, make sure it’s gone on. So what you’re supposed to do is supposed to marker that with a pen round there, and then we’ve just got our press gun. And it’s as easy as that. And if you have a look at that, it just crimps it onto fitting and it squashes that, squashes the O ring on.

So we’ve got the new boiler on the wall now. We did a mains flush before we started. We’re now going to connect our MagnaCleanse onto this, and we’re going to do a flush, we’re going to put some F3 chemicals in, and then after we’ve finished we’ll put some inhibitor in as well. So this system did have a Spirotech on, so I’ve just put this Fernox Omega on just for a few seconds, and already it’s got muck in there. So Fernox F3.

So while we’re finishing off now, the system can just flush. We can just spend loads and loads of time making sure the system’s clean because the MagnaCleanse there is doing this work while we have a chance to do other things. So I can finish flue off, screw the flue, I can brick up outside, just while this is doing this. So it just makes it so much easier. And that adaptor from Fernox is absolutely brilliant.

So we’ve been flushing it for a while now with thee MagnaCleanse. If you look at the pipes you can see they look very clear. So we’re going to take this off now. So let’s open these up and see what we’ve caught, if anything. So there you go. Let’s have a look at this one. Wow. Yeah. Just goes to show how good these MagnaCleanses are, very, very good. So we’ve just got this Fernox F1 inhibitor here, and just going to inject it in, into the filter there.

So we’re just doing the finishing touches now. So we’re just going to test it with care, analyse it, make sure the boiler is all safe. Test us high and test us low. And we’re going to fill this benchmark out, and then we’re going to send the warranty off for the customer, so the customer’s got piece of mind that it’s all taken care of for them.

Hope this video was of some use. Thanks for watching.

PLUMBING video installing a new Baxi 830 combi boiler in LEEDS installing a new combi boiler. Boiler installation Leeds. Installing a new baxi 830 combi boiler. Step by step. Flushing the system. Doing a magnacleanse. Real job with bad pipework.
Leeds plumber installing new combi boilers and central heating systems in Leeds. Baxi 800 combi boiler.

A short video demonstrating a system conversion. Removing a open vented boiler and installing a new combination boiler. This type of boiler installation will take between 1 and 1.5 days to complete. The customer at the particular job was very happy as her old boiler had let her down and she had been without heating of hot water for about a week!!

#CombiBoiler NEW BOILER, Baxi Platinum Combi Boiler Installation. Gas Boiler Installation. Boiler Installation. Central Heating. https://www.cchleeds.co.uk/services/boiler-installation
How to install a gas combi boiler. Step by step guide of installing a new Baxi platinum combo boiler. Including flushing and installing a Fernox Omega filter. How to install a combi boiler. http://cchleeds.co.uk/services/boiler-installation
Today we're working in Otley, near Leeds, and we're just installing a new combi boiler. We've got a nice flat wall here today, so we're just going to show you step-by-step how we do it.

The first thing, and one of the most important things, we protect the property.

We've got his Baxi Platinum there. So that's the boiler that we're installing today. So just going to open this up. Then when we open this, we'll have a look there. We just found the bag of all these hooks and things and all your fittings pack.

We've got your jig in there, just slides out. So if you can see there, all the boiler is still in the box so the boiler can be just kept nice and safe while we fit the jig on the wall, and then just mark all this out.

We've got this laser level here, so we can easily level the boiler up. One thing to point out with this, it must be installed by a Gas Safe registered engineer. If it's not installed by a Gas Safe registered engineer, then you will have no warranty with the boiler, and you will also, if you come to sell your property, you will not have the right certification that you'll need to actually sell the property. Always make sure that you have it done by a Gas Safe registered engineer.

We haven't got our car drill with us today, so what we've done is we've just stitched that. We've drilled a lot of 6 mil pilot bits all the way around for the flue. It's nice and neat, is that.

We put the scraps back in the box, and we left the foam stuff in the bottom, and now we can use that as a bin, keep our rubbish together. So we just got us caps to take out the bottom of here. Bit of water coming out. These are tested before they come out, so you should never have a faulty one on install because they'll all be tested. And now we're just going to take this cover off, just so it doesn't get bent.

So what we normally find is these nuts on this back, that doesn't line up very well, so you can't just tighten them up. It won't go on. See there, they're not in line. So all you need to do, is, see the nuts on the back, just slacken them nuts off, and then you'll be able to connect it up very easily. So just slacken them off, on the back of the valve. Then...

So we've connected all them on now, so now we can just tip them all up and just tighten the back nuts back up. I always do this first before I connect any pegs to it because if you connect the pegs it can be quite awkward to get them to line up, so this is just the way that I do it.

So I just connected the pressure relief pipe, and if you see there, it's bent. So these always come twisted or bent on the, on the backs of boilers. So you can, if you want, there's a little grip screw there you can just undo that and you can straighten it up a little bit, or you can just try to bent this pipe a little bit. All of the things I've seen, I've seen people cut this and then just put a socket on just to straighten it up by the one, so I've actually just twisted the pipe a little bit.

So I just drilled for the blow off now, and we just leave that. We're just gonna put some non-setting mastic in there. We don't want the copper to come in contact with the cement, because the cement will corrode the copper over time.

So we're just done with pipes now. So we've got this Fernox filter put in there, this Fernox, Omega filter, and they were just gonna do gas now.

So we've got the boiler up and running now, so we are just gonna check the emissions, we just got a chem analyzer there, so we just want to check that it's working safely. We've also got a flushing adapter on there, so that's flushing the system. With liner cleanse.

So we're just finishing up now, so we've installed this Baxi, this Baxi Platinum. This Baxi Platinum comes with 10-year parts and labour warranty. We've also got, we've installed a Fernox filter. So the Fernox filter comes with 25-year warranty. And we've also put, we've cleaned it out with Fernox F5, and we've also added a Fernox inhibitor F1 protector in afterward so that will protect the system.
New Boiler Yeadon, New Boiler Otley, New Boiler Leeds
Thank you for taking the time to watch our video, How to Instal a Combi Boiler.