You find that we are a full service heating and air conditioning service provider in Madera County serving Fresno, Bass Lake, Mariposa, Coarsegold, Oakhurst and surrounding areas. We work on:
Trane Furnace Repair
American Standard Furnace Repair
Goodman Furnace Repair
Janitrol Furnace Repair
Rheem Furnace Repair
RUUD Furnace Repair
Lennox Furnace Repair
Comfortmaker Furnace Repair
Heil Furnace Repair
Tempstar Furnace Repair
Amana Furnace Repair
Maytag Furnace Repair
Nordyne Furnace Repair
Intertherm Furnace Repair
Coleman Furnace Repair
Armstrong Furnace Repair
Carrier Furnace repair
Day and Night Furnace Repair
Payne Furnace Repair
Consolidated Industries Furnace Repair
Premier Furnace Repair
And more. We work on hot surface ignition systems, floor furnaces, wall furnaces, garage heating systems, mini-split ductless systems. We repair central heating and air conditioning systems including:
Trane Heating and Air Conditioning Repair and Installation
American Standard Heating and Air Conditioning Repair and Installation
Goodman Heating and Air Conditioning Repair and Installation
Janitrol Heating and Air Conditioning Repair and Installation
Rheem Heating and Air Conditioning Repair and Installation
RUUD Heating and Air Conditioning Repair and Installation
Lennox Heating and Air Conditioning Repair and Installation
Comfortmaker Heating and Air Conditioning Repair and Installation
Heil Heating and Air Conditioning Repair and Installation
Tempstar Heating and Air Conditioning Repair and Installation
Amana Heating and Air Conditioning Repair and Installation
Maytag Heating and Air Conditioning Repair and Installation
Nordyne Heating and Air Conditioning Repair and Installation
Intertherm Heating and Air Conditioning Repair and Installation
Coleman Heating and Air Conditioning Repair and Installation
Armstrong Heating and Air Conditioning Repair and Installation
Carrier Heating and Air Conditioning Repair and Installation
Day and Night Heating and Air Conditioning Repair and Installation
Payne Heating and Air Conditioning Repair and Installation
Consolidated Industries Heating and Air Conditioning Repair and Installation
Premier Heating and Air Conditioning Repair and Installation

Most heating repairs are less than $100. We are your furnace repair experts. Heat pumps repaired and Freon leaks fixed.
* Trane Furnace Repair
* American Standard Furnace Repair
* Carrier Furnace Repair
* Payne Furnace Repair
* Bryant Furnace Repair
* Goodman Furnace Repair
* Janitrol Furnace Repair
* Amana Furnace Repair
* Wall Furnace Repair
* Floor Furnace Repair
We repair and install all brands of home and commercial furnaces and air conditioners.
Visit our website at http://www.EmpireCares.com/ and download valuable coupons. Yelp Empire Reviews Yelp. For more information see one of our many websites at http://www.coarsegoldheating.com/ or http://www.oakhurstheating.com/ or http://www.empirecares.com/ Empire plumbing reviews. Empire air conditioning reviews. Empire heating reviews. Empire electric reviews.

Triton Showers - http://www.tritonshowers.com

A short video explaining the electrical requirements for an electric shower, in particular what to check before buying to ensure your intended purchase is compatible with your mains electric supply.

Instantaneous Electric Showers are still one of the most popular types of shower sold in the UK today. Which is why Triton manufactures an extensive range to suit all tastes and budgets.

An electric shower simply connects to a cold water supply and your mains electric, so it's versatile enough to suit any home no matter what your plumbing system.

They are easy to install and they give you and your family instant hot water - any time, day or night.

So, what are the electrical requirements you need to know before you can choose an electric shower?

First of, all electric showers need to connect to your mains electric supply.

More to the point, it must have its own dedicated supply from your consumer unit.

It must not be connected to a ring main, spur, socket outlet, lighting circuit or cooker circuit.

The important thing is to ensure that the electric supply is adequate for the shower and existing circuits.

Check that your consumer unit has a main switch rating of 80A or above and that it has a spare fuse way to take the fuse or Miniature Circuit Breaker (MCB) for the shower.

The correct rating of MCB or fuse will depend on the kilowatt rating of the shower that is to be fitted. For more information on kW ratings take a look at our "What is a kW rating?" video.

If your consumer unit has a rating below 80A, or if there is no spare fuse way, then the installation will not be straightforward.

It may require a new consumer unit serving the house or just the shower.

For your protection, a 30mA residual current device must be installed. This may be part of the consumer unit or a separate unit.

The size of electric cable you need from the consumer unit to the shower depends on a number of things, such as - the kilowatt rating of the shower and the method of installing the cable...

...i.e. is it, or will it, be surrounded by loft or wall insulation. As a result, the cable could be anything from 6mm, to 10mm, or even 16mm.

To obtain full advantage of the shower, use the shortest cable route possible from the consumer unit to the shower.

In any event, it is essential that individual site conditions are assessed by a competent electrician in order to determine the correct cable size and permissible circuit length.

Finally before your electrics can go into the shower unit, you need to install a 45 amp double-pole isolating switch into the circuit.

This can either be installed inside or outside of the bathroom, but it must be readily accessible to switch off after using the shower.

Once you've fitted the switch into the circuit, all you have to do is complete the cable to the shower.

Depending on the model of shower, the cable will enter through either the top, bottom, sides or back of the unit.

Simply connect into the terminal block making sure the connections are good and tight so there is no risk of the cable overheating.

The final thing to say is that all electric showers must be installed in accordance with all the relevant water supply, electrical and building regulations.

To find out what the plumbing requirements are for the installation of an electric shower, why not take a look at our complementary video "Electric Showers: Plumbing Requirements.

https://bh-electrical.co.uk/

https://www.londonelectricalandplumbing.co.uk/